- Rconstruction = 3.01 \(K·m^2 \over W\) Uconstruction = 0.33 \(W \over K·m^2\)
- Rsurface, internal = 0.04 \(K·m^2 \over W\) Rsurface, external = 0.13 \(K·m^2 \over W\)
- Rtotal = 3.18 \(K·m^2 \over W\) Utotal = 0.31 \(W \over K·m^2\)
- Layers
- Layer 1: Render Rlayer = 0.013 \(K·m^2 \over W\), Touter = 35 °C, Tinner = 34.95 °C
- Layer 2: Brickwork Rlayer = 0.298 \(K·m^2 \over W\), Touter = 34.95 °C, Tinner = 33.86 °C
- Layer 3: Air Cavity Rlayer = 0.175 \(K·m^2 \over W\), Touter = 33.86 °C, Tinner = 33.23 °C
- Layer 4: Insulation Rlayer = 2.5 \(K·m^2 \over W\), Touter = 33.23 °C, Tinner = 24.09 °C
- Layer 5: Plaster Rlayer = 0.026 \(K·m^2 \over W\), Touter = 24.09 °C, Tinner = 24 °C